Modern office spaces require advanced air conditioning systems that provide comfort to employees while maintaining energy efficiency. Ceiling cooling is an innovative solution that is gaining popularity among architects and investors due to its effectiveness and discreet form. At Onninen, we offer comprehensive ceiling cooling systems that are ideal for office spaces, conference rooms, and commercial facilities.
As a leader in the installation market, you will find modern solutions in our assortment that combine high cooling efficiency with energy savings and interior aesthetics. Our systems, available at all Onninen branches, ensure an even temperature distribution without the annoying drafts characteristic of traditional air conditioning.

Check air conditioning at Onninen warehouse
Why ceiling cooling is the future of offices
Contemporary offices are characterized by large glazing, open space, and high workstation density. These factors generate significant heat gains that traditional air conditioning systems often struggle to dissipate. From our many years of experience in the installation industry, it follows that ceiling cooling systems offer cooling power of about 50 W/m² of ceiling area, which, combined with wall cooling, provides comfortable working conditions.
Benefits for modern office spaces
- Invisibility of the system - installation hidden in the suspended ceiling does not take up wall space
- Quiet operation - no noise generated by traditional air conditioning fans
- Even temperature distribution - elimination of hot and cold zones in the office
- Energy savings - up to 40% lower energy consumption compared to conventional air conditioning
- Better hygienic conditions - no circulation of dust and allergens
Onninen offers systems from renowned manufacturers that cooperate with air-to-water heat pumps, providing year-round thermal comfort in heating mode in winter and cooling mode in summer.
Technical parameters of ceiling cooling systems
| Parameter | Value | Application |
|---|---|---|
| Cooling medium temperature | 16-20°C | Ceiling cooling |
| Cooling power | 40-60 W/m² | Office spaces |
| Panel thickness | 15-30 mm | Suspended ceiling |
| Response time to temperature change | 15-30 minutes | Automatic regulation |
Uponor Thermatop M systems - modern solutions for offices
In Onninen's assortment, we particularly recommend Uponor Thermatop M systems, which stand out with their seamless construction and the ability for quick installation without the use of tools. The system uses a multi-layer Uni Pipe PLUS with a diffusion barrier, ensuring long-lasting operation without corrosion.
Advantages of the Thermatop M system
The Thermatop M system is a solution designed for demanding office projects. Prefabricated modules measuring 2150x277 mm can be easily integrated with LED lighting, fire protection systems, or ceiling speakers. Our team of experts confirms that installation occurs by snapping the mounting rails into the CD profiles of the substructure, significantly speeding up project implementation.
As a leader in the installation market, Onninen provides access to complete Uponor systems along with distributors, circulation pumps, and control automation. Our branches throughout Poland guarantee quick order fulfillment and professional technical support at every stage of the project.
Installation and integration with office systems
Installing ceiling cooling in modern offices requires proper coordination with other installations. From our experience, the best results are achieved when cooperating with mechanical ventilation systems with heat recovery.
Key installation aspects
During installation, we pay special attention to controlling the dew point - the temperature of the cooling surface must be higher than the condensation temperature of water vapor. Onninen offers humidity and temperature sensors that automatically regulate the system's operating parameters, ensuring safe operation.
Our specialists recommend using dry construction technology, which allows for quick installation without the need for plastering. The systems available at Onninen use 15 mm thick plasterboard with factory-installed pipes, ensuring precise execution and durability of the installation.
Integration with lighting and electrical installations
Modern offices require the integration of ceiling cooling with LED lighting systems. In our projects, we use perforated ceiling panels that allow for the installation of fixtures directly in the cooling panels. This solution ensures optimal use of ceiling space while maintaining high cooling efficiency.
Energy efficiency and cooperation with heat pumps
The ceiling cooling systems available in Onninen's offer are characterized by exceptionally high energy efficiency. Cooperation with reversible heat pumps allows for achieving high EER coefficients due to the relatively high cooling medium temperature (16-20°C).
As an experienced provider of installation solutions, we recommend systems that operate in cooling mode with parameters of 16/20°C, and in heating mode with 35/30°C. These parameters are optimal for heat pumps, ensuring the highest energy efficiency throughout the year.
Comparison of energy consumption
| Cooling system | Energy consumption | User comfort |
|---|---|---|
| Split air conditioning | High | Drafts, noise |
| Ceiling cooling | Up to 40% lower | No drafts |
| Ducted air conditioning | Average | Average comfort |
Frequently asked questions
1. How does ceiling cooling work in offices?
Ceiling cooling works on the principle of thermal radiation. Cold water at a temperature of 16-20°C flows through pipes placed in ceiling panels, which absorb excess heat from the room, ensuring an even temperature distribution without drafts.
2. What cooling power do ceiling systems provide?
Ceiling cooling systems provide power of about 40-60 W/m² of ceiling area. In a typical office of 30 m², a cooling power of 1500-1800 W can be achieved, which often suffices for basic cooling needs.
3. Does ceiling cooling cooperate with heat pumps?
Yes, ceiling cooling works perfectly with reversible heat pumps. High parameters of the cooling medium temperature (16-20°C) allow the heat pump to achieve maximum energy efficiency, providing savings of up to 40% compared to traditional air conditioning.
4. How long does it take to install ceiling cooling in an office?
The installation of ceiling cooling in an office usually takes 2-5 working days. Dry construction systems, such as Uponor Thermatop M, are installed by snapping into CD profiles without the use of tools, significantly speeding up the installation process.
5. Is there a risk of condensation in ceiling cooling systems?
Modern ceiling cooling systems are equipped with safeguards against condensation. Humidity and temperature sensors automatically monitor the dew point and regulate the temperature
of the cooling medium, keeping it above the condensation temperature of water vapor.
6. What are the operating costs of ceiling cooling?
The operating costs of ceiling cooling are even 40% lower than traditional air conditioning. Thanks to cooperation with heat pumps and the high energy efficiency of the system, the monthly cooling costs for an office of 100 m² range from 150 to 300 PLN in the summer season.
Comprehensive project support from Onninen
As a leader in the installation market, Onninen provides not only a wide availability of products but also comprehensive support at every stage of the ceiling cooling project implementation. Our specialists will help you choose optimal solutions, taking into account the specifics of the office building, energy requirements, and investment budget.
In Onninen's offer, you will find everything needed to implement a modern office air conditioning system - from Uponor Thermatop M cooling panels, through distributors and automation, to heat pumps and control systems. All products are available immediately in our network of branches, ensuring timely execution of even the most demanding projects.
With many years of experience in the installation industry and partnerships with renowned manufacturers, we can guarantee the highest quality of the solutions applied and long-lasting, trouble-free operation of ceiling cooling systems in your office.