Smoke exhaust system control panels

(32 )

Control panel RZN 4408-M
D+H
1
3 490,00 zł/pcs
30.117.29
CKZ372
to order
Control panel RZN 4416-M
D+H
1
3 535,17 zł/pcs
30.109.09
CKZ378
to order
Compact smoke exhaust control panel with built-in button for smoke exhaust and ventilation 3 A, orange - RZN 4503-T
D+H
1
2 458,89 zł/pcs
30.107.30
HCM390
to order
Control panel RZN 4332-E9
D+H
1
5 902,77 zł/pcs
73.D00.25
CKZ326
to order
24 V door drive, force: 500 N / stroke: 500 mm / 1.0 A - DDS 54/50
D+H
1
3 144,29 zł/pcs
23.002.50
HCM402
to order
BS-CDC-PI01-M-VFI Console
D+H
1
171,46 zł/pcs
26.800.01
CKZ317
to order
BS-CDC-PA01-M-VFO Console
D+H
1
151,29 zł/pcs
26.800.03
CKZ401
to order
Console BS-CDC-PI01-O-VSI
D+H
1
232,99 zł/pcs
26.800.02
CKZ312
to order
Drive CDC-0252-0350-1-ACB
D+H
1
1 423,70 zł/pcs
26.100.37
CKZ348
to order
Drive CDC-0252-0600-1-ACB
D+H
1
1 729,27 zł/pcs
26.101.37
CKZ343
to order
Drive CDC-0252-0600-5-ACB M1-R
D+H
1
2 147,41 zł/pcs
26.106.05
CKZ336
to order
Chain drive VENTIC 24 V, 200 N / 250 mm / 0.35 A (silver) - VCD 203/250
D+H
1
645,73 zł/pcs
25.150.05
HCM397
to order
Surface-mounted housing for buttons LT / LF / RF / UT, type AP-LT-PL
D+H
1
37,32 zł/pcs
73.H01.02
HGD942
to order
Push button RT 45-ST-PL
D+H
1
658,82 zł/pcs
30.431.54
CKZ360
to order
UT 4U PL Button
D+H
1
122,04 zł/pcs
73.H01.04
CKZ367
to order
LT 43-U-SD-PL button
D+H
1
141,20 zł/pcs
73.H01.05
CKZ363
to order
FS 41 module
D+H
1
578,24 zł/pcs
30.550.60
CKZ350
to order
Optical, conventional smoke detector with socket - 3000PLUS/OP SET
D+H
1
170,45 zł/pcs
73.PK0.01
HCM395
to order
Electromagnetic door gripper (broken), 24V, force: 400 N / 67 mA - GTR 048000A10
D+H
1
365,11 zł/pcs
73.K00.05
HCM394
to order
24V electromagnetic door gripper, force: 400 N / 67 mA - GTR 048000A06
D+H
1
261,23 zł/pcs
73.K00.01
HCM392
to order
Gripper GTR048000A07/GR
D+H
1
199,70 zł/pcs
73.K00.02
CKZ357
to order
AM 44-Z module
D+H
1
457,90 zł/pcs
30.524.90
CKZ354
to order
Set KA-BS046-VFI
D+H
1
228,95 zł/pcs
26.ADC.KS
CKZ328
to order
Set KA-BS050-VFO
D+H
1
201,72 zł/pcs
26.ADG.KS
CKZ321
to order
24V electromagnetic door gripper, force: 400 N / 66 mA - GTR 048000A01
D+H
1
255,18 zł/pcs
73.K00.08
HCM393
to order
Gripper GTR063000A10
D+H
1
569,17 zł/pcs
73.K00.06
CKZ337
to order
Gripper GTR048000A07/WH
D+H
1
240,05 zł/pcs
73.K00.03
CKZ344
to order
Duct detector housing (requires base and detector) PROTEC 6000PLUS/UG4DP
D+H
1
1 427,98 zł/pcs
73.P00.04
HCM384
to order
Actuator ZA 105/500-K
D+H
1
1 047,89 zł/pcs
27.007.10
CKZ383
to order
Bracket GTR048000A12006
D+H
1
140,20 zł/pcs
73.K00.07
CKZ332
to order
Set KA-BS040-VSI
D+H
1
296,53 zł/pcs
26.ACW.KS
CKZ333
to order
Set VCD-BS004-VFI (silver)
D+H
1
228,95 zł/pcs
25.CAE.KS
CKZ341
to order



Smoke extraction system control units - a key element of fire safety

Smoke extraction units are the heart of every fire protection installation.   Their role is crucial to ensuring safety in buildings. In our daily practice, we see how important it is to choose the right solution. These control units control the entire smoke extraction process in the event of a fire. They manage smoke flaps and fans. They also coordinate the operation of other fire protection devices.

Onninen's offer includes a wide range of smoke extraction units. Models with different power and functionality are available. Here you will find devices from 2.5A to even 80A. This range allows you to choose a unit for each facility. Small shops or large production halls - we have the right solution for everyone.

Types of smoke extraction units available at Onninen

Our assortment includes control panels from various manufacturers.   We especially recommend proven brands such as Fumaro or D+H.   They are leaders in the smoke extraction industry. Their products are characterized by high reliability and technical advancement. We also offer control units from other renowned manufacturers.

Smoke extraction system control units are divided into several basic types:

  • Power supply units with buffer power supply
  • Control units without power supply
  • Weather stations
  • Control panels integrated with SSP systems

Each of these types has its application in specific facilities. Control units with a buffer power supply ensure continuity of operation. Even in the absence of power, the smoke extraction system remains operational. Control units without a power supply are lighter and cheaper. They work well in smaller installations.

How to choose the right smoke extraction system control unit?

Selecting the right control panel is a key issue for the security of the facility.   There are several important factors to consider when choosing.   The first is the size of the protected space. The larger the facility, the more efficient the control unit should be. The number of executive devices in the system is also important. This includes smoke flaps or smoke extraction fans.

Another aspect is the required functionality of the system. Some facilities require advanced control. Others will be satisfied with simpler solutions. Local fire regulations are also important. They may impose specific requirements for smoke extraction units.

At Onninen we often come across questions about selecting control units. Our experts will be happy to advise on the right solution. We analyze the individual needs of each client. We select the optimal control unit in terms of technology and economy.

Practical applications of smoke extraction system control units

Smoke extraction system units are used in a variety of facilities.   They are essential wherever fire safety is key. We can see this in a recent implementation for a large shopping centre. We used a 40A Fumaro control unit there. It manages the smoke flap system on the roof of the building.

Another interesting case was a project for a tall office building. Here, ensuring safe evacuation was key. We used a D+H control unit integrated with the SSP system. It controls the flaps in the staircases. It also provides aeration for the evacuation lifts.

In the case of industrial halls, we often use weather stations. They monitor weather conditions and adjust the system's operation. This prevents unnecessary alarms in the event of strong wind or precipitation.

Our experience shows that a well-selected control unit is essential. It ensures efficient operation of the entire smoke extraction system. This translates directly into the safety of people and property.

At Onninen we focus on comprehensive smoke extraction solutions.   We offer not only control panels, but also all system elements. Smoke flaps, actuators, sensors - we have a full range. We also provide professional advice and technical support. We invite you to contact our specialists. They will help you choose the optimal solution for each facility.