Fire-resistant telecommunication cable HTKSHekw FE180/PH90/E90 1x4x2.8 B10151
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 m
Fire-resistant telecommunication cable HTKSHekw FE180/PH90/E90 1x4x2.8 B10151
Fire-resistant telecommunication cable HTKSHekw FE180/PH90/E90
This halogen-free telecommunication cable is designed to provide reliable communication even in extreme conditions. The HTKSHekw FE180/PH90/E90 cable is distinguished by its high fire resistance, making it an ideal solution for installations in places with increased safety requirements. Its construction and materials guarantee the functionality of the circuit for a long time, even during a fire.
This cable is particularly recommended for use in public buildings, data centers, industrial facilities, and anywhere high fire resistance and the continuity of communication systems are required. A static screen (ekw) minimizes electromagnetic interference, ensuring stable signal transmission.
Construction and properties
The HTKSHekw FE180/PH90/E90 cable is made of high-quality materials that meet strict safety standards. It has copper conductors with a cross-section of 2.8 mm², which ensures adequate conductivity and minimizes voltage drop. Four cores in a single sheath facilitate installation and allow for flexible cabling. Additionally, the cable is characterized by the absence of halogen in its composition, which means that it does not release toxic gases during combustion – important for the safety of users and environmental protection.
According to tests, this cable can withstand high temperatures for a long time – maintaining electrical functions during a fire confirmed by EN 50200 and DIN 4102-12 standards. This means that in the event of a fire, the installation will function properly for at least 90 minutes (PH90), and the cable insulation will retain its properties for 3 hours (FE180).
Applications and compliance with standards
The HTKSHekw FE180/PH90/E90 cable is used in:
- Fire alarm systems
- Alarm systems
- Access control systems
- Telecommunication networks in public buildings
- Industrial installations exposed to high temperatures
- Cable routes E90 (according to DIN 4102 part 12)
The cable meets the requirements of the following standards:
- DIN 4102 part 12 (fire resistance)
- EN 50200 (maintenance of electrical functions during a fire)
- IEC 60331 (fire resistance)