Fire-resistant telecommunications cable YnTKSY 3x2x1.0 TN0010
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 m
Fire-resistant telecommunications cable YnTKSY 3x2x1.0 TN0010
Fire-resistant telecommunications cable YnTKSY 3x2x1.0
This cable is designed for fixed installations in fire alarm systems, as well as for connections in telephone exchanges and data transmission equipment. Its use in alarm systems, where reliability and resistance to high temperatures are critical, makes it an ideal choice for both professionals and building owners prioritizing safety. The cable is also suitable for smoke extraction systems and connections to devices activated upon fire detection—such as power cut-offs, elevators, and ventilation systems.
Construction and Properties
The YnTKSY cable features a design ensuring high fire resistance. It contains copper conductors insulated with PVC, twisted into pairs and then bundled together. The entire assembly is enclosed in a flame-retardant PVC sheath compliant with EN 60332-1-2 and EN 60332-3-24 standards, with an oxygen index exceeding 29. This ensures the cable will not propagate fire during a fire event. The use of solid Class 1 copper conductors guarantees stable signal transmission. Wire color coding complies with PN-92/T-90320 (90321), facilitating identification during installation.
Electrical and Mechanical Parameters
The cable operates at a working voltage up to 150V and withstands dielectric tests at AC 1500V and DC 2250V. Insulation resistance exceeds 200 MΩ·km, ensuring minimal signal loss. For 1 mm² conductors, loop resistance per kilometer is maximum 48 Ω. Capacitance is maximum 120 nF/km, and inductance is approximately 0.7 mH/km. The minimum bending radius is 10 times the outer diameter—critical for installation in confined spaces. The cable holds a CNBOP PIB certification confirming compliance with safety standards. Additionally, it is RoHS certified (2015/863/EU), indicating the absence of hazardous substances in its composition.
CERTIFICATES, APPROVALS, SAFETY, COMPLIANCE AND WARNINGS
Declaration of Conformity
The declaration of performance
Attachments