Gas detector DG-P0E.O3/N ozone, 1ppm el-ch sensor
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 pcs
Gas detector DG-P0E.O3/N ozone, 1ppm el-ch sensor
Gas detectors – reliable measurement and protection
The DG-P0E.O3/N gas detector is a stationary, measuring device designed to detect the presence of ozone in industrial and enclosed spaces. The device signals exceeding permissible concentrations, ensuring safety and enabling a quick response in case of a hazard. Equipped with a 4-20mA analog output, the detector is compatible with various control and alarm systems, simplifying integration with existing infrastructure.
Construction and application
Detectors from the DG/P series, including the DG-P0E.O3/N model, are designed to work with control units from various manufacturers. GAZEX recommends using DG/PV type detectors with dual outputs (4-20mA and 2-10V) or measuring-threshold control modules MDP-1.A/T, MDP-1 PLUS, MDP-4, MDP-8 and MDP-16. Integration with addressable modules MDD-1, MDD-1/T, MDD-1x/T and other central units accepting a 4-20mA signal is also possible.
The device finds application wherever continuous monitoring of ozone concentration is necessary – from laboratories and industrial plants to swimming pools and wastewater treatment plants. Precise measurement allows maintaining safe working conditions and environmental protection.
Key features and benefits
- Replaceable electrochemical sensor: Ensures long-term operation of the device – if necessary, only the worn sensor can be replaced, without the need to replace the entire detector.
- 4-20mA analog output: Enables easy integration with control and alarm systems and remote reading of measurement data.
- Thermal and linear compensation: Guarantees measurement accuracy even in changing environmental conditions.
- Built-in optical signaling: Two LED lamps indicate the device status and exceeding the alarm concentration thresholds.
- Modularity and simple installation: Facilitates the design and installation of the gas monitoring system – no calibration required at the installation site significantly shortens the start-up time.
- Accredited calibration: Detectors are calibrated in their own GAZEX Calibration Laboratory (PCA accreditation No. AP150), ensuring the reliability and accuracy of measurements.
- Measurement range 0 ÷ 1 ppm ozone: Allows precise monitoring of ozone concentration in a wide range of applications.
- Splash-proof housing (IP44): Provides protection against moisture and dust, enabling installation in harsh industrial conditions (with the recommended mounting position).
Additional information: the response time of the DG-P0E.O3/N detector is approximately 3 hours to achieve metrological readiness from the moment the power is switched on.