Fire-resistant telecommunication cable HTKSHekw FE180 PH90/E30-E90 4x2x1.4 red 1639 021 23
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 m
Fire-resistant telecommunication cable HTKSHekw FE180 PH90/E30-E90 4x2x1.4 red 1639 021 23
Fire-resistant telecommunication cable – safety and reliability in critical installations
This red telecommunication cable HTKSHekw FE180 PH90/E30-E90, manufactured by TECHNOKABEL S.A., is an advanced solution for systems requiring the highest level of fire protection. Designed for permanent connections in alarm, signaling, teletransmission and DSO systems, as well as for data transmission in industrial installations, it ensures continuous operation even in extreme conditions. The cable has certificates of conformity and approvals from the Scientific Research Centre for Fire Protection – PIB in Józefów, which confirms its high quality and compliance with stringent safety standards.
Construction and application
The cable has been designed for installations in facilities with stringent fire protection requirements, such as public buildings, hospitals, data centers or underground tunnels. Its construction guarantees not only effective protection against fire, but also minimizes the emission of toxic gases and smoke in the event of a fire – which is crucial for human safety. Thanks to its resistance to water (according to PN-EN 50200 Annex E), it can also be used in rooms with water extinguishing systems. It is used for the transmission of analog and digital signals and for the power supply to devices requiring continuous power during a fire (e.g. emergency lighting).
The cable consists of eight conductors with a cross-section of 1.4 mm², twisted in pairs and surrounded by a common static screen protecting against electromagnetic interference. The conductor insulation is made of halogen-free material, which further increases safety. The cable jacket is also halogen-free (HFFR), meeting the standards EN 50290-2-27 and VDE 0250-214 – HM2. This construction ensures the maintenance of the cable's function during a fire – i.e. continuous data transmission and power supply to critical devices.
Key features and benefits
- Fire resistance: Meets FE180 PH90/E30-E90 standards, providing high fire resistance and maintaining cable function during a fire.
- Halogen-free: Minimizes the emission of toxic gases and smoke in the event of a fire, increasing the safety of people and equipment.
- Shielding: Common static screen protects against electromagnetic interference, ensuring stable signal transmission.
- Water resistance: Can be used in rooms with water extinguishing systems (according to PN-EN 50200 Annex E).
- Durability: Made of high-quality materials ensuring long-lasting and reliable operation.
- Certificates: Has a Certificate of Conformity and a Certificate of Approval issued by the Scientific Research Centre for Fire Protection - PIB in Józefów.
- Application: Ideal for alarm, signaling, DSO systems and industrial installations requiring a high level of fire safety.