Heat pump BWW-1-21 - 20.8 kW, 3-phase, 400 V for outdoor installation, water-to-water 9146037
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 pcs
Heat pump BWW-1-21 - 20.8 kW, 3-phase, 400 V for outdoor installation, water-to-water 9146037
Operates directly with groundwater – no need for ground collectors
The BWW-1-21 heat pump extracts energy from groundwater, ensuring a constant source temperature (7–22 °C) and high efficiency throughout the year. It does not require ground collectors – only a properly located borehole or well is needed. This avoids costly earthworks and long investment periods.
Quiet operation and compact design – suitable for installation even in limited spaces
With a noise level of 43 dB(A) at 0/35 °C, the unit can be installed in suspended ceilings, alcoves, or technical rooms where quiet operation is essential. Dimensions of 740 × 600 × 650 mm and a weight of 189 kg mean it is not a custom-built device – it can be transported and installed without specialized equipment. IP24 protection rating ensures moisture resistance in boiler room environments.
Heating capacity of 20.8 kW at COP 5.5 – professional-grade efficiency
At a source temperature of 10 °C and a heating circuit temperature of 35 °C, the pump delivers exactly 20.8 kW of heat, with a Coefficient of Performance (COP) of 5.5 – meaning that for every 1 kWh of electrical energy drawn from the grid, it delivers over 5 kWh of heat. High efficiency performs particularly well at low circuit temperatures, making it ideal for underfloor or wall heating systems.
6 kW electric heater with modulation – support without interrupting operation
The integrated 6 kW electric heater operates modulatively – it does not switch on at full power but adds precisely the amount of heat required. This means: no temperature spikes during high domestic hot water (DHW) demand, and stable operation during periods of low source temperature. There is no need to install an external boiler or additional heater.
Safety features and compatibility – ready for integration with control systems
The unit features a built-in soft start – limiting inrush current, thereby reducing the load on the electrical installation. A switching valve enables automatic preparation of domestic hot water. The stainless steel plate heat exchanger is corrosion-resistant and easy to maintain. A phase loss and phase sequence sensor prevents damage due to connection errors.
Operation under pressure up to 3 bar – safe for both closed and open systems
The maximum working pressure for both the source and delivery circuits is 3 bar – sufficient for most water-to-water systems, both open (direct groundwater extraction) and closed (with circulation). However, it is not suitable for ground collectors – only for water-based sources.
Refrigerant R407C – stable and widely used
R407C is a refrigerant with excellent thermodynamic properties, well-known in commercial installations. It does not require specialized service tools or additional maintenance procedures.
Complete connection with WPM-1 controller
Using a 4-meter cable, the pump is ready for immediate connection to the WPM-1 controller – no separate control wiring or additional interfaces are required.