Overcurrent circuit breaker 6kA HN-C20/1N 194852
- 9010238067530
- 9010238063365
- 9010238072770
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 pcs
Overcurrent circuit breaker 6kA HN-C20/1N 194852
6kA overcurrent circuit breaker is a reliable protection for electrical installations, designed for both domestic and commercial applications. The HN-C20/1N model from Eaton, with a rated current of 20A and C characteristic, effectively protects circuits against overloads and short circuits. The breaking capacity of 6kA guarantees safe operation even in the event of high surge currents.
This single-pole (1P+N) circuit breaker with double terminals – for both wire and busbar connection – provides installation flexibility and ease of connection. The device's design allows power supply from both sides, further simplifying installation. It meets the requirements for coordination of insulation, ensuring a safe distance between the contacts. Mounting is done on a standard DIN TH 35 rail.
The C characteristic makes this circuit breaker ideal for loads with high inrush currents, such as motors or devices with electronics (e.g., induction cookers, LED lighting). This prevents unnecessary tripping of the circuit when starting these devices. The rated impulse withstand voltage of 4kV provides additional safety in case of overvoltages.
- Versatile application: ideal for socket circuits, lighting circuits and protection of RTV and household appliances.
- High reliability: compliance with EN 60898 and IEC 60947-2 standards guarantees safe and long-lasting operation.
- Easy installation: double terminals and universal power supply facilitate installation in any situation.
- Safety: protection against overloads, short circuits and potential fires caused by electrical failures.
- Durable construction: resistant to external factors and mechanical damage.
The HN-C20/1N circuit breaker is part of the xPole Home series from Eaton – products characterized by modern design, high quality workmanship and ease of use. Using this circuit breaker is an investment in safety and peace of mind, for both installers and end users. The device has a protection degree of IP20 and energy limitation class 3, which confirms its high safety parameters. Power losses are 3.7W at a rated voltage of 230V and a frequency of 50/60Hz. The cross-section of the connected conductor can range from 1 to 25 mm², both solid and stranded. The ambient temperature in operating conditions is in the range of -25 to 75°C.
CERTIFICATES, APPROVALS, SAFETY, COMPLIANCE AND WARNINGS
Declaration of Conformity