DPN N VIGI C10A, 30mA, Type A, 1-pole +N RCD with overcurrent protection A9D32610

from 1 pcs279,75 zł
gross / pcs
z 5 pcs
z 5 pcs
Onninen Index:CBD096
Manufacturer's code:A9D32610
EAN:
13606480472050
  • 3606480472053
Bulk packaging:1 / 6 / 432 pcs


Suggested products


TECHNICAL DATA

Sales unit dimensions and weight: 1 pcs

length/width/height/weight:0,1 m / 0,08 m / 0,04 m / 0,215 kg
Customs code:85362010

DPN N VIGI C10A, 30mA, Type A, 1-pole +N RCD with overcurrent protection A9D32610

Multifunctional RCBO with Overcurrent Protection

This 1-pole + N RCBO with overcurrent protection, iDPN Vigi C10A series, 30mA, type A, is a comprehensive solution for protecting electrical installations. It provides effective protection against overloads, short circuits and electric shock, combining the functions of an MCB and RCD in one device. This is particularly important in installations requiring a high level of safety, both in residential and commercial buildings.

Application and Design Features

The circuit breaker is designed for mounting on DIN rails in distribution boards. Its compact width of 2 modules allows for optimal use of space in the distribution board. Characteristic C provides delayed tripping during short-term overloads, which is important when connecting devices with motors or other elements generating high inrush current. The rated residual current of 30mA guarantees a quick response in the event of a leakage current to earth, minimizing the risk of electric shock. Equipped with a two-pole lever indicating the type of tripping (overcurrent or residual current) and optical indicators Visi-Trip and Visi-Safe, it facilitates diagnostics and fault identification.

Safety and Functionality for Professionals

The circuit breaker design has been designed with installers in mind. The ability to check the correct operation using the "T" test button (once a year for the first 7 years of use) allows for regular verification of the device's efficiency. The circuit breaker meets the requirements of EN/IEC 60898 and EN/IEC 60947-2 standards, confirming its compliance with the highest safety standards. The rated short-circuit breaking capacity Icn is 6kA, providing effective protection of the installation in the event of a short circuit. The cross-section of solid conductors from 1 to 16 mm² and stranded conductors from 1 to 10 mm² provides flexibility when selecting cables tailored to specific installation needs. Additionally, the lack of the need to disassemble the entire busbar during device replacement significantly saves time during service and modernization of the installation.

No need to dismantle the entire busbar, a huge time saver!
The largest area for markers among competitors.
Padlocks increasing safety and comfort of work.
The cross-section dedicated to the cable will always depend on the amperage of the device.
One iC60 circuit breaker is compliant with two standards, construction and industrial - EN/IEC 60 898 and EN/IEC 60 947-2.
Class 2 insulation.
Short-circuit capacities depending on the rated current and voltage can be correspondingly higher (iC60N has Icu - 50kA in current ranges from 0.5 to 4 A, and 10 kA from 6 to 63 A, iC60H has Icu = 70 kA from 0.5 to 4 A and 15 kA from 6 to 63 A, iC60L has Icu = 100 kA from 0.5 to 4 A and Icu = 25 kA for 6 to 63 A), meaning there is no need to use additional fuse inserts! No