Condensing gas boiler MCR4 24/35 BIC with integrated DHW heater. 7857050
reviews: 1
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 pcs
Condensing gas boiler MCR4 24/35 BIC with integrated DHW heater. 7857050
Condensing boiler with integrated DHW heater
Wall-mounted gas boiler with a built-in 45 liter stainless steel DHW tank equipped with an exchanger coil. This tank does not require an external heater – the installation is compact, and hot water preparation takes place directly within the boiler, without additional components.
The air-gas module allows for power modulation from 10% to 100%, enabling precise power adjustment to current demand. The non-return valve allows operation with C43p pressure flue gas discharge systems – ideal for modern installations with forced ventilation. The Ø60/100 mm air-flue connection is supplied as standard, and the boiler is homologated for connection to both a chimney (B23p, C93) and to distribution (C53) or collector (C43P) systems.
The stainless steel toroidal heat exchanger – covered by a 5-year warranty – ensures durability and high efficiency. Efficiency at full load reaches up to 105.8%, and nitrogen oxide emissions are below 21 mg/kWh, corresponding to the highest ecological class.
Control system and gas adaptation
The boiler is equipped with the Gas Adaptive System – an electronic system that automatically adjusts combustion parameters to the type of gas: E, Lw, Ls, or propane/butane. When operating on Ls gas, an additional conversion kit is required – there are no technical limitations, only the necessity for proper configuration.
Control is managed via the E-Pilot console with an intuitive interface and weather compensation function. An AF60 outdoor temperature sensor is required for operation (available as an accessory). It is possible to connect a Smart TC modulating thermostat, which enables remote control via smartphone or tablet – the application works on Android and iOS and signals faults in real time.
Hydraulic design and safety
The brass hydraulic module contains an A-class modulated pump with an energy efficiency index EEI < 0.23 – which is the highest available class for pumps in this category. The diverter valve between the heating and DHW circuits is mounted on the supply side – minimizing heat loss and ensuring rapid response.
Safety features:
- safety valve for the heating circuit at 3 bar
- safety valve for the DHW circuit at 8 bar
Expansion vessels:
- 10 liters for the heating circuit
- 2 liters for the DHW circuit
Additionally, the SCB-17B board is available, which allows for direct integration and management of an additional heating circuit without the need to install an external controller.
Future-proofing
The boiler is designed to operate with gas containing up to 20% hydrogen blend – requiring no modifications when switching to more ecological fuel. This is not just a solution for today, but an investment for the coming years.