Overcurrent circuit breaker ETIMAT 10 3p B6 002125712
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 pcs
Overcurrent circuit breaker ETIMAT 10 3p B6 002125712
Reliable protection of electrical installations – ETIMAT 10 circuit breaker
ETIMAT 10 circuit breaker is a proven protection element in electrical installations – both in residential buildings and public and industrial facilities. Its task is to protect circuits against the effects of overloads and short circuits, ensuring safe use and minimizing the risk of failure. The design and parameters of the circuit breaker allow for its versatile use in various installations.
Functionality and flexibility
The ETIMAT 10 circuit breaker is characterized by high functionality, which translates into convenient installation and subsequent operation. The ability to mount additional auxiliary contacts (PS ETIMAT 10) and overcurrent releases (DA ETIMAT 10) allows you to adapt the circuit breaker's characteristics to the specific needs of a given installation. Power can be supplied from the top or bottom, and the double insulated busbar connection (top and bottom) facilitates integration with existing infrastructure. The contact position indicator and "ON/OFF" marking on the actuating lever ensure intuitive operation and quick identification of the device status. Additionally, the ability to seal the lever in the "On" and "Off" positions increases safety and prevents accidental adjustment. Each circuit breaker has a unique EAN code for easy identification.
Technical parameters and compliance with standards
The ETIMAT 10 circuit breaker with a rated current of 6A is characterized by a B characteristic, which means a quick response to an increase in short-circuit current. The rated short-circuit breaking capacity (Icu) is 15kA at 230V and 400V, and the rated short-circuit breaking capacity Icn according to EN 60898 is 10kA at 230V and 400V. The circuit breaker is designed to operate in an ambient temperature from -25°C to +55°C, and its IP20 degree of protection provides protection against finger contact and the ingress of solid objects. The cross-section of the connected conductor can range from 1 to 25 mm² (single-core or multi-core). The rated insulation voltage Ui is 500V. The circuit breaker meets the requirements of IEC/EN 60898-1 and IEC 60947-2 standards, which guarantees its reliability and safety of use. The energy limitation class is 3. The width of the circuit breaker is 3 module pitches, which facilitates its integration with other devices in the distribution board.
CERTIFICATES, APPROVALS, SAFETY, COMPLIANCE AND WARNINGS
cert_title_deklaracja_zgodności_(ce)
Certificate of Conformity
Attachments