Residual current circuit breaker with overcurrent protection iDPNNVigi-B20-30-AC B 20A 1-pole 30 mA type AC A9D55620
from 1 pcs176,21 zł
gross / pcs
z 2 pcs
z 2 pcs
Series:Acti 9 iDPN Vigi
Onninen Index:HEK127
Manufacturer's code:A9D55620
EAN:
13606480472630
- 3606480472633
Bulk packaging:1 / 6 / 432 pcs
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 pcs
length/width/height/weight:0,098 m / 0,04 m / 0,08 m / 0,211 kg
Customs code:85362010
Residual current circuit breaker with overcurrent protection iDPNNVigi-B20-30-AC B 20A 1-pole 30 mA type AC A9D55620
Residual Current Device (RCD) iDPNNVigi-B20-30-AC is an essential element of electrical installation, ensuring user safety. It features a Type B tripping characteristic and AC sensitivity, meaning it can react to short-circuit and leakage currents above 30 mA. This RCD has an energy limitation class of 3 and two poles – one neutral and one phase. Its rated voltage is 230 V, and the rated current is 20 A.
The iDPNNVigi-B20-30-AC RCD is manufactured with an IP20 degree of protection, guaranteeing its resistance to dust and finger contact. The device's width, expressed in modules, is two, allowing for easy mounting in a distribution box or other designated location.
The rated differential current for this model is 0.03 A – this is the minimum value required for the device to
The iDPNNVigi-B20-30-AC RCD is manufactured with an IP20 degree of protection, guaranteeing its resistance to dust and finger contact. The device's width, expressed in modules, is two, allowing for easy mounting in a distribution box or other designated location.
The rated differential current for this model is 0.03 A – this is the minimum value required for the device to
No need to disassemble the entire busbar, Mega time saving! . The largest marker field among the competition. . Padlock locks for increased safety and comfort of work. The cross-section dedicated to the cable will always depend on the amperage of the camera. One iC60 circuit breaker complies with two standards, Construction and Industrial - EN/IEC 60 898 and EN/IEC 60 947-2. 2nd class of insulation. The short-circuit capacity, depending on the value of the rated current and voltage, may be correspondingly higher (iC60N has Icu - 50kA in the current ranges from 0.5 to 4 A, and 10 kA from 6 to 63 A, iC60H has Icu = 70 kA from 0, 5 to 4 A and 15 kA from 6 to 63 A, iC60L has Icu = 100 kA from 0.5 to 4 A and Icu = 25 kA for 6 to 63 A), so there is no need for
CERTIFICATES, APPROVALS, SAFETY, COMPLIANCE AND WARNINGS
cert_title_certyfikat_pep_(certyfikat_profilu_ekologicznego_produktu)[eko_label]
- Acti9 - iCV40N - Residual Current Breaker with Overcurrent 1P+N 16A C curve 6kA AC type 30mA - Produ
cert_title_deklaracja_rohs
Other
- Acti9 - iCV40N - Residual Current Breaker with Overcurrent 1P+N 16A C curve 6kA AC type 30mA - Produ