Backflow preventer flanged type BA4760 DN80 149B3097

from 1 pcs7 427,38 zł
gross / pcs
temporary unavailable
Brand SOCLA
Series:BA4760
Onninen Index:HAM772
Manufacturer's code:149B3097
EAN:3660770191130
Bulk packaging:1 pcs


Suggested products


TECHNICAL DATA

Sales unit dimensions and weight: 1 pcs

length/width/height/weight/volume:0,6 m / 0,4 m / 0,4 m / 32,7 kg / 0,096 m3
Customs code:84159000

Backflow preventer flanged type BA4760 DN80 149B3097

Backflow preventer – protection of the water supply network

This BA4760 type backflow preventer, with a nominal diameter of DN80, is a key element protecting water installations from contamination caused by backflow. This device finds application in both commercial and residential installations where high reliability and protection against potential hazards are required. The design based on a double check valve with an intermediate chamber and a drain valve ensures effective separation of zones and minimizes the risk of transferring contaminants.

Construction and principle of operation

The BA4760 isolator consists of two check valves separated by an intermediate chamber. In the event of backflow, an air gap is created in the chamber, which physically separates the supply zone from the drain zone. This design guarantees effective protection against backflow of media, which is particularly important in water systems with high hygienic requirements. Additionally, the device has pressure gauge connections allowing constant monitoring of its operation.

The body is made of gray cast iron, and the internal elements – check valves – of bronze, brass and PPO. Membranes and seals are made of EPDM, which ensures resistance to water and other media. The entire construction has been designed to ensure long-term and trouble-free operation. It should be remembered to mount the device in a horizontal position and to provide a drain to the sewer for water collected in the intermediate chamber.

Installation and maintenance – key to reliability

Correct installation of the backflow preventer is crucial for its proper operation and maintaining the manufacturer's warranty. In accordance with PN-EN1717, shut-off valves should be installed before and after the isolator to allow for its maintenance and verification of correct operation. A sediment filter is also recommended to be installed directly before the valve to prevent contaminants from entering the device. It is also important to slowly open the shut-off valve before the isolator and protect it from the effects of frost and high temperatures. Regular checks of the technical condition and maintenance will allow maintaining high efficiency of the device for a long time.