Power switch with motor drive 200 A HIB420M

from 1 pcs8 705,85 zł
gross / pcs
to order
Brand HAGER
Onninen Index:CVF194
Manufacturer's code:HIB420M
EAN:3250613191368
Bulk packaging:1 pcs


Suggested products


TECHNICAL DATA

Sales unit dimensions and weight: 1 pcs

length/width/height/weight/volume:0,317 m / 0,239 m / 0,244 m / 10,2 kg / 0,018 m3
Customs code:85365080

Power switch with motor drive 200 A HIB420M

Power transfer switch with motor drive – automatic switching between sources

This device is used for safe and automatic switching between two power sources – e.g., the main grid and an emergency generator. It has an integrated motor drive that performs the switching without manual intervention, making it ideal for installations requiring power continuity: hotels, hospitals, data centers, or production lines.

It is designed as main, safety and maintenance disconnect – allowing physical isolation of the circuit for service or fault. It does not function as an emergency stop: it does not instantly cut off current in case of a sudden fault, but provides controlled switching between states.

Installation and wiring – specific requirements

The device is permanently mounted and intended solely for installation in distribution panels. Installation on a DIN rail, in a 4‑hole panel, or front‑center is not possible – the only correct method is to install inside a properly prepared panel.

Connection of the main circuits is done via cable clamps. For 200 A current the minimum copper conductor cross‑section is 95 mm², maximum – 120 mm². Flexible busbars with a cross‑section of 2 × 95 mm² can also be used. Bolt tightening torque is: recommended 20 N·m, maximum 45 N·m – exceeding this limit may damage the clamp.

Control is performed via control circuit terminals (312–317, 313–317, 316–317, etc.). Control wires should have a cross‑section of 1.5–2.5 mm². Access to the terminal strip is required for their connection – this requires removing the top cover. After wiring, the cover must be closed again.

Indicators and operating status

The device has two LED indicators:

  • green – indicates presence of supply voltage

  • red – indicates manual operation mode or device unavailability

These indicators are integral to the device and visible directly on its enclosure – no external monitoring required.

Durability and safety

  • Operates at voltage 380–690 V AC, continuous current 200 A

  • Switching capacity at 400 V: 131 kW

  • Rated conditional short‑circuit current: 50 kA

  • Rated withstand short‑time current: 12 kA

  • Front‑panel protection rating: IP00 – the device must be enclosed in a distribution board

There are no optional voltage release devices or other accessories. The device operates solely as designed: a pure switching mechanism with motor drive.

Installation and commissioning may be performed only by qualified personnel. In case of damage – even minor – full replacement of the device is recommended.


CERTIFICATES, APPROVALS, SAFETY, COMPLIANCE AND WARNINGS