Circuit breaker iC60N-D10-3 D 10A 3-pole A9F05310
- 3606480441547
Suggested products
TECHNICAL DATA
Sales unit dimensions and weight: 1 pcs
Circuit breaker iC60N-D10-3 D 10A 3-pole A9F05310
Overcurrent circuit breaker iC60N-D10-3 is a three-pole device designed to protect electrical installations against the effects of overloads and short circuits. It is characterized by a rated current of 10A and has a D tripping characteristic, which means it is particularly resistant to surge currents, typical of devices with motors or power supplies.
This model of circuit breaker combines the advantages of building (EN/IEC 60898-1) and industrial (EN/IEC 60947-2) protection, offering a wide range of applications. Its design allows for easy installation and removal, as well as ensuring safety during maintenance. The ability to connect wires with a cross-section from 1 to 25 mm² (solid) and from 1 to 16 mm² (stranded) provides flexibility in wire selection.
- Versatility: Compliance with two standards – building and industrial – means that the circuit breaker can be used in various facilities: residential estates, commercial properties and industrial buildings.
- Safety: VisiTrip and VisiSafe indicators make it easy to identify the status of the circuit breaker – a red VisiTrip indicator signals a trip caused by a disturbance, and a green VisiSafe confirms that the contacts are open and it is safe to work on the installation.
- Installation comfort: The ability to remove a single device without removing the busbar significantly reduces working time during modernization or repairs. In addition, double terminals allow connection of wires from both the top and the bottom.
- High breaking capacity: The rated short-circuit breaking capacity Icn is 6 kA at 230 V and 400 V, and Icu reaches up to 20 kA at 230 V and 10 kA at 400 V, ensuring effective protection of the installation against the effects of short circuits.
- Durability and reliability: Made of high-quality materials and with a protection degree of IP20, it guarantees long-lasting and trouble-free operation in working conditions with a temperature of -35°C to 70°C.
The iC60N-D10-3 circuit breaker has energy limitation class 3 and surge category 4. Its width expressed in number of modules is 3, which facilitates its integration with other devices in the distribution board. Power losses are only 2.3 W, which translates into efficient use of electrical energy. The rated impulse withstand voltage Uimp is as high as 6 kV, providing additional safety in the event of overvoltage.
CERTIFICATES, APPROVALS, SAFETY, COMPLIANCE AND WARNINGS
cert_title_certyfikat_pep_(certyfikat_profilu_ekologicznego_produktu)[eko_label]
cert_title_deklaracja_rohs
Deklaracja DOC CE (Deklaracja zgodności CE)
Attachments